1、濟南防水http://www.liveevil.cn/分析目前的框架結構住宅工程中填充墻,基本上為非承重的灰砂磚或小型砌塊。灰砂磚和小型砌塊在運輸與施工過程中容易產生破損,缺棱掉角等缺陷。若在施工中使用了受破損 或由于設備管暗裝的需要對已砌外墻進行鑿打,人為地造成外墻砌體破損,也較容易在外墻 砌體形成滲水處;溫差引致混凝土結構梁柱與填充墻結合處產生開裂。
Jinan waterproof analyze the current framework housing project infilled, substantially non-load-bearing sand-lime bricks or small blocks. Sand-lime brick and small block in the transport and construction process prone to breakage,missing edge off angle defects. When used in the construction of the pipe due to equipment that is damaged or concealed need to build external walls have been caulked, artificially created damaged masonry facades, but also relatively easy to form a water seepage at the masonry facades; temperature difference caused by concrete structural beams columns and infill walls junction cracking.
2、濟南防水介紹工人在砌體施工中未嚴格按施工規范操作,砌筑砂漿不飽滿,特別是豎縫砂漿。此外,砂漿的強度不達標或干磚上墻,使砂漿中的水份被磚吸收,從而造成砂漿強度偏低,導 致磚和砂漿分離,砌體整體剛度下降,產生墻體裂縫。外墻抹灰層一次性打底太厚或為保證全高垂直度而使局部打底偏厚,又未采取適當 加強措施而產生裂縫;墻體層表面太光滑,結合不良;外墻大面積打底而基層未設分格線, 產生不規則收縮裂縫。
Jinan waterproof introduce workers not in strict accordance with construction norms operating in masonry construction, masonry mortar is not full, especially vertical mortar joints. In addition, the strength of non-compliance or mortar dry brick wall, mortar brick in the water is absorbed, resulting in low strength of mortar, brick and mortar lead to separation, the overall stiffness of masonry fall, resulting in cracks in the wall. External plastering layer is too thick or one-time rendering to ensure the full high vertical partial thickness leaving the local base, they did not take appropriate measures to strengthen and cracks; too smooth surface of the wall layer, combined with bad; the external walls of a large area of play The grass does not have a bottom ruled lines, resulting in irregular shrinkage cracks.
3、濟南防水http://www.liveevil.cn/談到飾面磚鋪貼空鼓或鋪貼砂漿不飽滿,面磚與砂漿間空隙部分易形成貯水容器;面磚 勾縫不密實或勾縫龜裂,密縫勾縫遺漏都是使雨水從表面滲入,造成積水,從而引起滲漏;窗臺、遮陽板和雨篷等水平構件的表層施工中未找坡度,甚至倒坡,造成倒返水或積水,也容易造成外墻面滲水。
Speaking Jinan waterproof decorative brick paving or paving mortar hollowing is not full, the gap between the brick and mortar part is easy to form water containers; brick pointing is not dense or pointing cracks, pointing omissions are
tightly sewn so that rain water from penetrate the surface, resulting in stagnant water, causing leakage; surface construction windowsill, sun visors and awnings and other horizontal member not find the slope, even down slope, causing pour rakeback or water, it is likely to cause the outer wall of water seepage.